FM2XCCH
Certificates:
Application
Used as fixed installation cables in various electromechanical and electronic
equipments of marine vehicles, in most areas & open deck in ships.
Due to its’ overall screen the electromagnetic interference is
minimized.
*Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see
technical information section
Download Pdf
CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
INSULATION : Cross linked polyethylene compound (XLPE).
SEPARATOR : Separating tape over pairs.
INDIVIDUAL SCREEN : Electrolytic, tinned, stranded, copper drain wire and aluminum tape screen over each pair
OVERALL SCREEN : Electrolytic copper braided screen (Min. 90%coverage) (Tinned copper wire braid on reguest)
INNER COVERING : Separating foil.
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Black or Grey.
INSULATION : Cross linked polyethylene compound (XLPE).
SEPARATOR : Separating tape over pairs.
INDIVIDUAL SCREEN : Electrolytic, tinned, stranded, copper drain wire and aluminum tape screen over each pair
OVERALL SCREEN : Electrolytic copper braided screen (Min. 90%coverage) (Tinned copper wire braid on reguest)
INNER COVERING : Separating foil.
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Black or Grey.
CONSTRUCTION : IEC 60092 / 376
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT: IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
FİRE RESISTANCE : IEC 60331 / 21, / IEC 60331 / 1-2
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : : 6xD
RATED VOLTAGE : 150 / 250 V
TEST VOLTAGE : 1,5 kV
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT: IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
FİRE RESISTANCE : IEC 60331 / 21, / IEC 60331 / 1-2
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : : 6xD
RATED VOLTAGE : 150 / 250 V
TEST VOLTAGE : 1,5 kV
Cross Section (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Bending Radius Fixed Min. (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
---|---|---|---|---|---|
2x2x0,5 | 9.9 | 124 | 60 | 40.4 | 9 |
4x2x0,5 | 11.5 | 182 | 69 | 40.4 | 6 |
7x2x0,5 | 14 | 296 | 84 | 40.4 | 5 |
12x2x0,5 | 18 | 540 | 108 | 40.4 | 5 |
16x2x0,5 | 20 | 570 | 120 | 40.4 | 4 |
18x2x0,5 | 21 | 618 | 126 | 40.4 | 4 |
24x2x0,5 | 22.6 | 765 | 136 | 40.4 | 4 |
2x2x0,75 | 11.5 | 158 | 69 | 26 | 11 |
4x2x0,75 | 13.2 | 235 | 80 | 26 | 8 |
7x2x0,75 | 16.2 | 375 | 98 | 26 | 7 |
12x2x0,75 | 21.3 | 594 | 128 | 26 | 6 |
16x2x0,75 | 24.3 | 750 | 146 | 26 | 5 |
18x2x0,75 | 25.7 | 835 | 155 | 26 | 5 |
24x2x0,75 | 30.3 | 1090 | 182 | 26 | 5 |
2x2x1 | 12.1 | 175 | 73 | 19.2 | 13 |
4x2x1 | 14.5 | 295 | 87 | 19.2 | 9 |
7x2x1 | 17.2 | 428 | 104 | 19.2 | 8 |
12x2x1 | 22.6 | 680 | 136 | 19.2 | 7 |
16x2x1 | 25.8 | 860 | 155 | 19.2 | 6 |
18x2x1 | 27.1 | 942 | 163 | 19.2 | 6 |
24x2x1 | 31.9 | 1230 | 192 | 19.2 | 6 |
2x2x1,5 | 14.7 | 260 | 89 | 12.8 | 17 |
4x2x1,5 | 17.2 | 390 | 104 | 12.8 | 12 |
7x2x1,5 | 20.5 | 575 | 123 | 12.8 | 10 |
12x2x1,5 | 27.8 | 934 | 167 | 12.8 | 9 |
16x2x1,5 | 31 | 1175 | 186 | 12.8 | 8 |
18x2x1,5 | 32.8 | 1305 | 197 | 12.8 | 7 |
24x2x1,5 | 39 | 1790 | 234 | 12.8 | 7 |