SupremeFlex SmF M2XCH
Certificates:
Application
Used as fixed installation cables in various electromechanical and electronic
equipments of marine vehicles, in most areas & on open deck in ships.
*Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see
technical information section
Download Pdf
CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
SCREEN : Electrolytic copper braided screen (90% coverage). (Tinned copper wire braid on reguest)
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Black or Grey.
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
SCREEN : Electrolytic copper braided screen (90% coverage). (Tinned copper wire braid on reguest)
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Black or Grey.
CONSTRUCTION : IEC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : 8 x D
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : 8 x D
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
Cross Section (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Bending Radius Fixed Min. (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
---|---|---|---|---|---|
3×35 | 22.6 | 1275 | 181 | 0.554 | 107 |
3×50 | 26.8 | 1740 | 215 | 0.386 | 137 |
3×70 | 30.5 | 2425 | 244 | 0.272 | 168 |
3×95 | 33.2 | 3050 | 266 | 0.206 | 201 |
3×120 | 39.2 | 3970 | 314 | 0.161 | 233 |
3×150 | 43 | 4845 | 344 | 0.129 | 268 |
3×185 | 47.8 | 5806 | 383 | 0.106 | 303 |
3×240 | 53.2 | 7662 | 426 | 0.0801 | 356 |
4×35 | 26.3 | 1655 | 211 | 0.554 | 107 |
4×50 | 30.2 | 2240 | 242 | 0.386 | 137 |
4×70 | 35 | 3160 | 280 | 0.272 | 168 |
4×95 | 38.7 | 4085 | 310 | 0.206 | 201 |
4×120 | 43 | 5140 | 344 | 0.161 | 233 |
4×150 | 47.3 | 6255 | 378 | 0.129 | 263 |
4×185 | 52.7 | 7565 | 422 | 0.106 | 303 |
4×240 | 58.1 | 9990 | 465 | 0.0801 | 356 |