SupremeFlex SmF M2XH-FFR
Certificates:
Application
Used as fixed installation cables in various electromechanical and electronic
equipments of marine vehicles, where sustainable connection during fire is required.
*Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see
technical information section
Download Pdf
CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
FIRE BARRIER : Mica tape.
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
SCREEN : Electrolytic copper braided screen (90% coverage). (Tinned copper wire braid on reguest)
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Orange or Green or Black.
FIRE BARRIER : Mica tape.
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
SCREEN : Electrolytic copper braided screen (90% coverage). (Tinned copper wire braid on reguest)
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Orange or Green or Black.
CONSTRUCTION : IEC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT: IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
FİRE RESISTANCE : IEC 60331 / 21, / IEC 60331 / 1-2
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : : For cables D ≤ 25 mm 4xD
For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT: IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
FİRE RESISTANCE : IEC 60331 / 21, / IEC 60331 / 1-2
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : : For cables D ≤ 25 mm 4xD
For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
Cross Section (mm2) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Bending Radius Fixed Min. (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
---|---|---|---|---|---|
3×35 | 22.4 | 1150 | 134 | 0.554 | 107 |
3×50 | 26.6 | 1600 | 160 | 0.386 | 137 |
3×70 | 30.3 | 2200 | 182 | 0.272 | 168 |
3×95 | 32.8 | 2865 | 197 | 0.206 | 201 |
3×120 | 38.6 | 3660 | 232 | 0.161 | 233 |
3×150 | 42.3 | 4445 | 254 | 0.129 | 268 |
3×185 | 47.2 | 5525 | 284 | 0.106 | 303 |
3×240 | 52.6 | 7110 | 316 | 0.0801 | 356 |
4×35 | 26.2 | 1525 | 158 | 0.554 | 107 |
4×50 | 30.1 | 2115 | 181 | 0.386 | 137 |
4×70 | 35 | 2900 | 210 | 0.272 | 168 |
4×95 | 38.2 | 3775 | 230 | 0.206 | 201 |
4×120 | 43.7 | 4850 | 263 | 0.161 | 233 |
4×150 | 46.8 | 5850 | 281 | 0.129 | 268 |
4×185 | 52.2 | 7275 | 314 | 0.106 | 303 |
4×240 | 57.7 | 9365 | 347 | 0.0801 | 356 |