SupremeFlex SmF M2XH

M2XCH (NOFI)
February 18, 2020
SupremeFlex SmF M2XCH
February 18, 2020
  • TaskLorem ipsum dolor sit amet enim. Etiam ullamcorper. Suspendisse a pellentesque dui non felis.

SupremeFlex SmF M2XH

Certificates:

Application

Used as fixed installation cables in various electromechanical and electronic
equipments of marine vehicles, in most areas & on open deck in ships.

*Minimum recommended installation temperature -15°C

For core identification, diameter tolerances and current ratings etc. see
technical information section



Download Pdf
CONDUCTOR : Electrolytic, stranded, annealed copper wire IEC 60228 Class 5 (Class 2 and / or tinned on request)
INSULATION : Cross linked polyethylene compound (XLPE).
INNER COVERING : Separating foil.
OUTER SHEATH : Halogen-free, flame retardant, polyolefin based compound (SHF1).
COLOR : Black or Grey.
CONSTRUCTION : IEC 60092 / 353
TESTS AND MATERIAL : IEC 60092 / 350-360
FLAME RETARDANT : IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A
HALOGEN CONTENT : IEC 60754 / 1-2
SMOKE EMISSION : IEC 61034 / 1-2 (DIN EN 50268 / 1-2)
OZON RESSıTANCE : IEC 60811 / 403
SHIELDING EFFECTIVENES (FOR EMC TYPE) : DIN EN 50147-1
WORKİNG TEMPERATURE : -40°C / + 90°C
MİN. BENDİNG RADIUS (FIXED) : For cables D ≤ 25 mm 4xD
For cables D > 25 mm 6xD
RATED VOLTAGE : 0,6 / 1 kV
TEST VOLTAGE : 3,5 kV
Cross Section (mm2) Nominal Overall Diameter (mm) Approximate Weight (kg / km) Bending Radius Fixed Min. (mm) Max Resistance of Conductors at 20°C (ohm / km) Current Carrying Capacity at 45°C (A)
3×35 21.2 1125 128 0.554 107
3×50 25.6 1575 154 0.386 137
3×70 29.1 2240 175 0.272 168
3×95 31.8 2845 191 0.206 201
3×120 37.4 3640 225 0.161 233
3×150 41.3 4415 248 0.129 268
3×185 46 5350 276 0.106 303
3×240 51.5 7150 309 0.0801 356
4×35 25.1 1495 151 0.554 107
4×50 28.8 2045 173 0.386 137
4×70 33.7 2960 203 0.272 168
4×95 37 3760 222 0.206 201
4×120 41.3 4795 248 0.161 233
4×150 45.5 5795 273 0.129 268
4×185 51 7050 306 0.106 303
4×240 56.3 9420 338 0.0801 356
 