These cables are intended for use as control and power cables aboard ship and on off-shore oil rings. The cables are constructed in accordance with the recommended practice for marine cable for use on fixed or floating facilities, IEEE 1580. Excellent resistance to oil, abrasion petrochem fluids, moisture salty water and sunlight.

Download Pdf

CONDUCTOR : Soft annealed stranded bare or tinned copper per IEEE1580
SEPARATION TAPE : Polyester tape if required
INSULATION / JACKET : Type P flame retardant cross-linked polyolefin compound, X110 meeting the requirements for IEEE 1580 Type P and UL1309
JACKET : CPE, Flame retardant, oil abrasion, chemical resistant thermosetting compound as required IEEE1580
ARMOR : Basket weave bronze wire armour per IEEE1580 and UL1309/ CSA C22.2 No.245. Tinned copper wire available by request
SHEATH : CPE, Flame retardant, oil abrasion, chemical and sunlight resistant thermosetting compound as required IEEE1580
OUTER SHEATH COLOR : Black
REFERENCE STANDARD : IEEE 1580, UL 1309, CSA C22.2 No.245
TEMPERATURE RATING : Untel 125°C / UL CSA 110°C / IEEE 100°C
FLAME RETARDANT : IEEE 1202 & IEC 60332-3 cat. A
COLD BEND/IMPACT : -40°C / -35°C (CSA 22.2 No.03)
Size AWG Diameter (inches) Weight (lbs/Mft) 110ºC A 100ºC A
160.5191811716
140.5832282725
120.6262763331
100.6693524341
80.8184775552
60.9466507470
41.16510049592
21.3071374126122
11.4311675149143
1/01.552015171164
2/01.6452424197188
3/01.8143106229218
4/02.053652264252
2622.2664434311294
3132.4184919340321
3732.5175718378361
4442.686864435411
5352.9868250464443
6463.3019258540516
7773.51110945588562
 